KAMJET electric pump units deliver up to 4,000 bar or 520 l/min, free of exhaust gases on site, quiet and also available in an ATEX version.
Pressure max.
4,000 bar
Flow rate max.
520 l/min
Exhaust gas on site
none
Speed (VFD)
down to 1:10
Configurations
T, B, BSS, C
Explosion protection
ATEX possible

Free Enquiry
Tell us the pressure, flow rate, medium and preferred configuration in the form. KAMAT designs the pump, motor and control system and prepares a quotation.
| Electric Units | |
|---|---|
| 912 KB | |
| 9.6 MB | |
Versatile, Ready-to-Operate Pump Units with Electric Drive from KAMAT
Special areas of application require individual high-pressure systems, which we can realise from the first project idea to the ready-to-operate unit with 100% vertical integration. This also applies to the electric units. Depending on the high-pressure application, our customers can choose between different power transmission components, PLC controls, measuring systems, data transmission, remote controls, pneumatic and electric valve controls, mobile chassis and sound insulation. But even the electric pump units supplied on the base frame are fully ready for operation and can be used directly by the customer.
Electric units have the advantage that they can be operated without emissions and at extremely low noise levels. With ATEX certification, the electric units can also be used in potentially explosive atmospheres.
KAMAT high-pressure systems are traditionally used in industrial high-pressure cleaning and pressure testing, in mining and in water hydraulics. In addition, special solutions for special fluids or for meeting explosion protection requirements are also part of the KAMAT range.
Technical Features of the KAMAT Electric High-Pressure Pump Units
A KAMAT electric pump unit is a fully equipped high-pressure system that combines a powerful KAMAT pump with an electric drive. The units deliver flow rates up to 520 l/min or operating pressures up to 4,000 bar. Depending on the application, different versions are available, from compact base frame solutions to sound-insulated container systems. All variants are modular, available in an ATEX version and suitable for stationary and mobile use.
Depending on Emission Regulations, Electric Pump Units Can Be the Right Choice
In principle, we can drive all our complete units with either diesel or electric motors. Depending on the application and project, both types of unit may even be required, as in the industrial application of net cleaning. If the units are used in several countries with different emission regulations, an electric unit with a locally approved diesel generator can be the right choice.
Your Benefits at a Glance
Emission-Free and Quiet
No exhaust gas on site, very low noise, also for enclosed spaces
ATEX Version
With ATEX certification for potentially explosive atmospheres
Speed Via Frequency Converter
VFD operation down to 1:10 of rated speed
For Continuous Operation
For stationary plants in continuous operation
One Unit for Several Countries
Power supply via a locally approved diesel generator if required
In-House Manufacturing
Development, manufacturing, software and control cabinet construction at KAMAT in Witten
Technical Data
Equipment of the KAMJET electric units. KAMAT defines the exact design according to your application, your requirements and the operating conditions.
| Pump | KAMAT plunger pump from all 12 series (triplex and quintuplex), up to 4,000 bar or 520 l/min, designed for the available inlet pressure |
|---|---|
| Drive | Electric motor, usually a three-phase motor; VFD operation down to 1:10 of rated speed possible; optionally hydraulic drive |
| Control system | PLC control, optionally fully automatic; measuring systems, data transmission and remote control; pneumatic or electric valve control |
| Configurations | T: mobile with soundproof hood · B: on base frame · BSS: noise-reduced on base frame · C: container for transport and outdoor use |
| Design | Compact, low-vibration and sound-insulated; horizontal or vertical; with or without fluid tank |
| Water supply | Stainless, central drainage |
| Version | Customer-specific, adapted to the climate zone of the site, ATEX possible |
Data Sheet Electric Units
Segments and Typical Applications
Typical fields of application for the electric units. KAMAT designs the unit for your operating point based on your enquiry.
Free Enquiry
Tell us the pressure, flow rate, medium, place of use and preferred configuration. KAMAT designs the pump, motor and control system and prepares a quotation.
On request, KAMAT carries out the acceptance run in Witten as well as commissioning, training and maintenance on site (Service). For short-term needs, pumps and units available immediately are on hand.
or call us directly: +49 2302 89 03 0
Frequently Asked Questions About the KAMJET Electric Units
An electric pump unit is a ready-to-operate unit consisting of a high-pressure pump with electric motor drive and often other components such as control system, valves and protection systems. It is used to pump liquids such as water, oil or chemical media under high pressure. KAMJET electric units deliver up to 4,000 bar or 520 l/min.
Electric pump units pump reliably, energy-efficiently and without emissions. Further advantages:
- Compact, low-maintenance design
- Long service life and robustness in continuous operation
- Precise controllability and integration into automated systems
- Low operating costs
Depending on the version, electric pump units are suitable for a wide range of industrial applications, including:
- High-pressure applications in the steel, mining and energy sectors
- Mechanical and plant engineering
- Water hydraulics and cleaning systems
- Process industry (e.g. for cooling or chemical circuits)
Electric pump units differ from diesel-driven units mainly in the drive concept, the operating conditions and the maintenance effort:
- Emission-free operation: electric units emit no exhaust gases and are therefore suitable for enclosed spaces or emission-sensitive environments.
- Lower maintenance effort: electric motors are generally subject to less wear than combustion engines. Oil and filter changes on the combustion engine as well as fuel management are not required.
- High energy efficiency: electrically driven pump units work more efficiently, especially in continuous operation or with constant power demand.
- Main area of use: diesel units are often used mobile and independent of the power grid, for example on construction sites or in emergency operation. Electric pump units are particularly suitable for stationary plants in continuous operation.
A typical electric pump unit consists of:
- one or more high-pressure pumps
- an electric motor (usually a three-phase motor)
- coupling, base frame, sound insulation and cooling system (depending on the application)
- control and monitoring units
- optional: valve technology, sensors, safety devices
The configuration can be adapted individually in the KAMAT modular system according to medium, pressure requirement and area of use.
The most important selection criteria include:
- Pumped medium (e.g. water, oil or chemicals)
- Operating pressure and flow rate
- Ambient conditions (e.g. temperature, explosion protection)
- Standards and certifications (e.g. ATEX)
- Connection and control technology
KAMAT configures the unit to suit the respective application.