The KAMAT pressure drop calculator determines the pressure drop in high-pressure hoses and pipes for water and shows the pressure the pump must deliver for the required nozzle pressure. At 60 l/min, 40 m of thermoplastic hose and a 13 mm inside diameter, around 18 bar is lost.
How the Pressure Drop Calculator Works
Enter flow rate, inside diameter, line length and line type, and select whether the pressure at the nozzle or at the pump is known. The calculator shows the other pressure, the flow velocity and the power loss.
The calculation is based on the Darcy-Weisbach equation: Δp = λ · (L / d) · (ρ · v² / 2). The friction factor λ follows from the Reynolds number and the roughness of the line (Colebrook, Swamee-Jain approximation). Couplings, bends and fittings are included as the sum of the loss coefficients ζ, the height difference as ρ · g · h.
Example: at 60 l/min (15.9 gpm) through 40 m (131 ft) of thermoplastic hose with a 13 mm (0.51 in) inside diameter, the water flows at 7.5 m/s (24.7 ft/s). The friction loss is 17.4 bar, with ζ = 1 the total is around 18 bar (257 psi) and 1.8 kW of power loss. For 2,500 bar at the nozzle, the pump must deliver around 2,518 bar. The nozzle calculator gives you nozzle pressure and flow rate, the pump finder the matching pump series.
KAMAT Tools App
The pump finder and nozzle calculator are also available in the KAMAT Tools app.
What Determines the Pressure Drop
Single Line
Pressure at pump = pressure at nozzle + friction + minor losses + height. Q flow rate, d inside diameter, ζ couplings and bends, h height difference.
Inside Diameter
Example: 60 l/min, 40 m of thermoplastic hose, ζ = 1. The loss falls roughly with the fifth power of the inside diameter.
Branched Line
Calculate each section with its own flow rate and add up the losses to the nozzle. The pump pressure follows from the branch with the highest demand.
Pressure Drop in High-Pressure Hoses: Guide Values per 10 m
The table shows the friction loss in bar per 10 m (33 ft) of thermoplastic hose for water at 20 °C, without couplings and bends. The loss rises linearly with length: 40 m gives four times the value.
| Inside diameter | 20 l/min | 40 l/min | 60 l/min | 100 l/min | 150 l/min |
|---|---|---|---|---|---|
| 8 mm | 6.3 | 22.9 | 49.3 | 131.6 | 289.0 |
| 10 mm | 2.1 | 7.5 | 16.1 | 42.4 | 92.4 |
| 13 mm | 0.6 | 2.1 | 4.4 | 11.3 | 24.5 |
| 16 mm | 0.2 | 0.8 | 1.6 | 4.0 | 8.6 |
| 19 mm | 0.1 | 0.3 | 0.7 | 1.7 | 3.7 |
| 25 mm | < 0.1 | 0.1 | 0.2 | 0.5 | 1.0 |
Size the Pump for Your Line
Tell us the pressure at the nozzle, the flow rate and the line. KAMAT sizes pump and nozzle to match your system.
Frequently Asked Questions About the Pressure Drop Calculator
With the Darcy-Weisbach equation, from flow rate, inside diameter, length and roughness of the hose. The loss rises roughly with the square of the flow rate and linearly with length. At 60 l/min, 40 m of thermoplastic hose and a 13 mm inside diameter, the result with ζ = 1 is around 18 bar.
It has the largest effect: the loss falls roughly with the fifth power of the diameter. At 60 l/min, 40 m of hose and ζ = 1, around 65 bar is lost with a 10 mm inside diameter, around 18 bar with 13 mm and around 6 bar with 16 mm. The inside diameter counts, not the nominal size.
From 8 m/s (26 ft/s) the calculator recommends checking a larger inside diameter, because wear and pressure drop rise sharply. This is a guide value. The manufacturer of a given hose states its permissible values.
The calculator uses the density and viscosity of water at ambient pressure. Compressibility and the pressure dependence of viscosity are not considered, so above 2,000 bar the actual loss is slightly higher. The result is a preliminary sizing; KAMAT provides binding values for the specific operating point.
A larger inside diameter has the strongest effect, followed by a shorter line and fewer couplings and bends. If that is not enough, the pump must make up for the loss: the pump finder shows the series for the required pump pressure.